Solenoid valves (hazardous location)
Description
Explosion-proof solenoid valves are used to control a volume flow (e.g. P->A for 2/2 or P->A // A->T for 3/2). If the solenoid is energised, the valve changes its position. The control valve is actuated directly via an explosion-proof solenoid. It is typically used as a directly actuated valve or as a pilot valve for larger nominal sizes.
The explosion protection allows it to be used in EX areas. For the solenoid, a choice can be made between molded (m), flameproof (d) and intrinsically safe solenoids (ia).
Symbol
Technical data
| Size: | DN2-DN6 |
| Pressure range: | PN420 (DN6) and PN700 (DN2/DN3) |
| Material: | Steel, aluminium, brass, etc. |
| Voltage: | 12 VDC to 230 VAC |
| Function: | 2/2, 3/2, 4/2, 4/3 (NO / NC) |
| Media: | HFA, HLP, clear water, natural gas |
| Options: | Manual operation, detent, limit switch |
| Flow rate: | Up to 15l/min |
| Ex protection class: | Exd, Exia, Exme, Exde |
| Directive: | ATEX, IECEx, INMETRO, UL/CSA |